BHXQR - DELTA-LITE FIBERGLASS CASTING TAPE
- MSDS: BHXQR
- Manufacturer: PERMACEL TAPE DIV AN AVERY CO
- Product Name: DELTA-LITE FIBERGLASS CASTING TAPE
- National Stock Number: 6150-01-196-6204
Product Identification
Product ID:DELTA-LITE FIBERGLASS CASTING TAPE
MSDS Date:01/01/1987
FSC:6150
NIIN:01-196-6204
MSDS Number: BHXQR
Responsible Party
NEW BRUNSWICK, NJ 08903
US
Emergency Phone: 800-526-2459
Info Phone: 800-526-2459
Cage: 99742
Contractor
Cage: 99742
Ingredients
POLYPROPYLENE POLYOL DIPHENYL METHANE DIISOCYANATE
CAS: 9048-57-1
Fraction By Weight: 31-34%
METHYLENE BISPHENYL ISOCYANATE (MDI) (SARA III)
CAS: 101-68-8
RTECS: NQ9350000
Fraction By Weight: 5-8%
OSHA PEL C, 0.02 PPM
ACGIH TLV: 0.005 PPM; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ALUMINUM (SARA III)
CAS: 7429-90-5
RTECS: BD0330000
OSHA PEL 15MG/M3 DUST/5 FUME
ACGIH TLV: 10MG/M3 DUST; 9192
FIBERGLASS KNIT FABRIC
Fraction By Weight: 54%
OSHA PEL 15 MG/M3(TOTAL DUST)
ACGIH TLV: 10 MG/M3 (DUST)
POLYETHYLENE CORE
CAS: 9002-88-4
RTECS: TQ3325000
Fraction By Weight: 2%
Hazards
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: AT <80F, VAPORS ARE
MINIMAL DUE TO THE LOW VAPOR PRESSURE. IF HEATED BEFORE CURING
ISOCYANATES, IRRITATION OF THE RESPIRATORY TRACT AND ACUTE NERVOUS
SYSTEM DEPRESSION. SKIN & EYE C ONTACT: PRIMARY IRRITATION.
CHRONIC: REPEATED OR PROLONGED OVEREXPOSURE MAY RESULT IN ALLERGIC
SENSITIVITY OR REACTION.
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:CONTACT: EYE AND SKIN IRRITATION WITH POSSIBLE
SKIN SENSITIZATION. INGESTION MAY CAUSE IRRITATION AND POSSIBLE
CORROSIVE ACTION ON THE MOUTH AND STOMACH TISSUE. VOMITING MAY
OCCUR. MAY CAUSE BLOCKAGE OF THE G.I.TRACT.
Medical Cond Aggravated by Exposure:SKIN CONDITION SUCH AS DERMITITIS.
First Aid
First Aid:INHALATION: REMOVE FROM EXPOSURE, RESTORE BREATHEIN, KEEP
WARM & QUIET, NOTIFY A PHYSICIAN. EYES: FLUSH IMMEDIATELY WITH
PLENTY OF WATER FOR 15 MINUTES. GET IMMEDIATE MEDICAL ATTENTION.
SKIN: WASH WIT H SOAP AND WATER. CONSULT WITH A PHYSICIAN. REMOVE
CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE. INGESTION: SEEK
IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:PMCC
Flash Point:>350F,>177C
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS ISOCYANATE VAPORS.
Accidental Release
Spill Release Procedures:EXPOSED PREPOLYMER WILL REACT WITH AMBIENT
MOISTURE AND POLYMERIZE (HARDEN). A DILUTE AMMONIA SOLUTION (10%)
WILL NEUTRALIZE UNREACTED PREPOLYMER.
Neutralizing Agent:A DILUTE AMMONIA SOLUTION (10%)
Handling
Handling and Storage Precautions:STORAGE TEMPERATURES SHOULD NOT EXCEED
75F TO PREVENT PREMATURE POLYMERIZATION OF THE PRODUCT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:NORMAL MECHANICAL VENTILATION DURING CAST APPLICATION.
RECOMMEND LOCAL EXHAUST VENTILATION DURING CAST REMOVAL.
Protective Gloves:RUBBER OR VINYL
Eye Protection:SAFETY GLASSES
Other Protective Equipment:USE LONG SLEEVE & LONG LEG CLOTHING. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE. DO NOT REUSE CONTAMINATED
CLOTHING.
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING OR USING
WASHROOM.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:392F,200C
Vapor Pres:NEGLIGIBLE
Spec Gravity:1.23-PREPOLYMER
pH:4-6
Solubility in Water:SLIGHT
Appearance and Odor:ROLLED GAUZE 3 INCH X 4 YDS.
Percent Volatiles by Volume:NIL
Stability
Stability Indicator/Materials to Avoid:NO
WATER, STRONG ALKALI, ALCOHOLS, METAL COMPOUNDS, SURFACE ACTIVE AGENTS.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Conditions to Avoid Polymerization:POLYMERIZATION MAY OCCUR IF MATERIAL
IS HEATED FOR LONG PERIODS.
Disposal
Waste Disposal Methods:DISPOSE OF IN A MANNER THAT COMPLIES WITH LOCAL,
STATE, AND FEDERAL REGULATIONS. HARDENED CAST MATERIAL IS NOT
CLASSIFIED AS AN HAZARDOUS WASTE AND MAY BE DISPOSED OF IN AN
ORDINARY LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.